QUALITY FACTORS AND ABSORBED DOSE EQUIVALENCIES
Absorbed Dose Equal | ||
Quality Factor | to a Unit Dose | |
TYPE OF RADIATION | (Q) | Equivalenta |
X, gamma, or beta radiation and | 1 | 1 |
high-speed electrons | ||
Alpha particles, multiple-charged | 20 | 0.05 |
particles, fission fragments and heavy | ||
particles of unknown charge | ||
Neutrons of unknown energy | 10 | 0.1 |
High-energy protons | 10 | 0.1 |
a Absorbed dose in rad equal to 1 rem or the absorbed dose in gray equal to 1 Sv.
MEAN QUALITY FACTORS, Q, AND FLUENCE PER UNIT DOSE EQUIVALENT FOR MONOENERGETIC NEUTRONS
Fluence per Unit | Fluence per Unit | |||
Neutron | Quality | Dose Equivalentb | Dose Equivalentb | |
Energy | Factora | (neutrons | (neutrons | |
(MeV) | (Q) | cm-2 rem-1) | cm-2 Sv-1) | |
(thermal) | 2.5 x 10-8 | 2 | 980 x 106 | 980 x 108 |
1 x 10-7 | 2 | 980 x 106 | 980 x 108 | |
1 x 10-6 | 2 | 810 x 106 | 810 x 108 | |
1 x 10-5 | 2 | 810 x 106 | 810 x 108 | |
1 x 10-4 | 2 | 840 x 106 | 840 x 108 | |
1 x 10-3 | 2 | 980 x 106 | 980 x 108 | |
1 x 10-2 | 2.5 | 1010 x 106 | 1010 x 108 | |
1 x 10-1 | 7.5 | 170 x 106 | 170 x 108 | |
5 x 10-1 | 11 | 39 x 106 | 39 x 108 | |
1 | 11 | 27 x 106 | 27 x 108 | |
2.5 | 9 | 29 x 106 | 29 x 108 | |
5 | 8 | 23 x 106 | 23 x 108 | |
7 | 7 | 24 x 106 | 24 x 108 | |
10 | 6.5 | 24 x 106 | 24 x 108 | |
14 | 7.5 | 17 x 106 | 17 x 108 | |
20 | 8 | 16 x 106 | 16 x 108 | |
40 | 7 | 14 x 106 | 14 x 108 | |
60 | 5.5 | 16 x 106 | 16 x 108 | |
1 x 102 | 4 | 20 x 106 | 20 x 108 | |
2 x 102 | 3.5 | 19 x 106 | 19 x 108 | |
3 x 102 | 3.5 | 16 x 106 | 16 x 108 | |
4 x 102 | 3.5 | 14 x 106 | 14 x 108 |
aValue of quality factor at the point where the dose equivalent is maximum in a 30-cm diameter cylinder tissue-equivalent phantom.
bMonoenergetic neutrons incident normally on a 30-cm diameter cylinder tissue-equivalent phantom.
Fla. Admin. Code Ann. R. 64E-5.106
Rulemaking Authority 404.042, 404.051, 404.061 FS. Law Implemented 404.022(2) FS.
New 1-1-94, Formerly 10D-91.113.