D.C. Mun. Regs. tit. 12, subtit. 12-I, 12-I12

Current through Register Vol. 71, No. 36, September 6, 2024
Section 12-I12 - NORMATIVE REFERENCES

Under heading "ASHRAE" in Section 12 of ASHRAE 90.1, strike reference to "ANSI/ASHRAE Standard 62.1-2007Ventilation for Acceptable Indoor Air Quality" and insert a new standard in its place in the Energy Conservation Code-Commercial Provisions to read as follows:

Reference

Title

ASHRAE

1791 Tullie Circle, NE, Atlanta, GA 30329

ANSI/ASHRAE Standard 62.1-2013

Ventilation for Acceptable Indoor Air Quality

Under heading "ASHRAE" in Section 12 of ASHRAE 90.1, insert a new reference in the Energy Conservation Code-Commercial Provisions to "ANSI/ASHRAE Standard 189.1-2014" to read as follows:

ASHRAE

1791 Tullie Circle, NE, Atlanta, GA 30329

ANSI/ASHRAE Standard 189.1-2014

Standard for the Design of High-Performance Green Buildings Except Low-Rise Residential Buildings

Under heading "ASTM International" in Section 12 of ASHRAE 90.1, insert new references in the Energy Conservation Code-Commercial Provisions to read as follows:

ASTM International

100 Barr Harbor Dr., West Conshohocken, PA 19428-2959

ASTM E1827-11

Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door

ASTM E2813-12

Standard Practice for Building Enclosure Commissioning

Under heading "Canadian General Standards Board" in Section 12 of ASHRAE 90.1, insert new references in the Energy Conservation Code-Commercial Provisions to read as follows:

Canadian General Standards Board (CGSB)

Place du Portage III, 6B1, 11 Laurier Street, Gatineau, Quebec, K1A 1G6 Canada

CAN/CGSB-149.10-M86

Determination of the Airtightness of Building Envelopes by the Fan Depressurization Method

CAN/CGSB 149.15-96

Determination of the Overall Envelope Airtightness of Buildings by the Fan Pressurization Method Using the Building's Air Handling Systems

Under heading "United States Department of Energy" in Section 12 of ASHRAE 90.1, insert a new reference in the Energy Conservation Code-Commercial Provisions to read as follows:

United States Department of Energy

Office of Energy Efficiency & Renewable Energy, 1000 Independence Ave., SW, Washington, DC 20585

ENERGY STAR Multifamily Midrise T&V Protocols, 8.1

Fan Pressure Testing; Sampling Requirements

D.C. Mun. Regs. tit. 12, subtit. 12-I, 12-I12

Final Rulemaking published at 67 DCR 5679 (5/29/2020)