Rule 12-G307 - HANDRAILS AND GUARDRAILS

Strike Section 307.1 of the International Property Maintenance Code in its entirety and insert a new Section 307.1 into the Property Maintenance Code in its place to read as follows:

307.1

General. Every exterior and interior flight of stairs having more than three risers shall have a handrail on one side of the stair and every open portion of a stair, landing, balcony, porch, deck, ramp or other walking surface which is more than 30 inches (762 mm) above the floor or grade below shall have guards. Handrails shall not be less than 30 inches (762 mm) in height or more than 42 inches (1067 mm) in height measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces. Guards shall not be less than 30 inches (762 mm) in height above the floor of the landing, balcony, porch, deck, or ramp or other walking surface.

Exception:Guards shall not be required where exempted by the Building Code.