Rule 12-A3105 - AWNINGS AND CANOPIES

Strike Section 3105.1 of the International Building Code in its entirety and insert new Section 3105.1 to the Building Code in its place to read as follows:

3105.1

General.Awnings and canopies shall comply with the requirements of this Section 3105, other applicable sections of the Construction Codes, the Zoning Regulations and other applicable requirements. Awnings or canopies projecting over or into public space shall also comply with Section 3202.12.

[no change to Sections 3105.2, 3105.3, and 3105.4]

Insert new Sections 3105.5, 3105.6, 3105.7 and 3105.8 in the Building Code to read as follows:

3105.5

Fixed or permanent awnings. The minimum clearance from the sidewalk or any other space used by the public to the lowest part of any fixed or permanent awning shall be 8 feet (2438 mm). Fixed or permanent awnings installed above the first story shall not project more than 5 feet (1524 mm) from the face of the building.

Exceptions: Above doors on detached one and two family dwellings, and townhouses not more than three stories above grade in height with a separate means of egress, the minimum clearance from the sidewalk or any other space used by the public to the lowest part of the awning shall be 80 inches (2032 mm).

3105.6

Retractable awnings. The minimum clearance from the sidewalk or any other space used by the public to the lowest part of any retractable awning shall be 8 feet (2438 mm). Retractable awnings shall be securely fastened to the building and, in the fully extended position, no part of the awning shall be closer than 12 inches (305 mm) to the vertical plane of the lot line. Retractable awnings shall be equipped with a mechanism or device for raising and holding the awning in a retracted or closed position against the face of the building.

Exceptions: Above doors on detached one and two family dwellings and townhouses not more than three stories above grade in height with a separate means of egress, the minimum clearance from the sidewalk or any other space used by the public to the lowest part of the awning shall be 80 inches (2032 mm).

3105.7

Canopies.Canopies shall not extend closer than 2 feet (610 mm) from the lot line. The minimum clearance from the sidewalk or any other space used by the public to the lowest part of any canopy shall be 8 feet (2438 mm).

3105.8

Lettering on awnings or canopies. Lettering on awnings or canopies shall comply with Appendix N or any superseding regulations adopted pursuant to the Sign Legislation.