The CG-3 zone is intended to permit high-density mixed-use development with a focus on employment and provide for the establishment of South Capitol Street as a monumental civic boulevard.
The development standards in Subtitle K §§ 503.3 through 503.10 shall control the bulk of buildings in CG-3 zone.
The maximum permitted FAR in the CG-3 zone shall be 6.5 or 7.8 FAR with IZ. Non-residential floor area shall be the total gross floor area of the building not dedicated to uses in one (1) of the following categories:
The maximum permitted building height, not including the penthouse or rooftop structure, in the CG-3 zone shall be ninety feet (90 ft.). Subtitle K § 510 contains design-related conditions on height and upper story setbacks for South Capitol Street, a designated street of Subtitle K § 508.
The maximum permitted height of a penthouse or rooftop structure in the CG-3 zone shall be twenty feet (20 ft.), and the maximum number of stories shall be one (1) plus a mezzanine, except that a second story for penthouse mechanical space shall be permitted.
The rear yard requirements for the CG-3 zone are as follows:
No side yard is required for the principal building; however, any side yard provided on any portion of the principal building shall be at least two inches (2 in.) per one foot (1 ft.) of height, and no less than five feet (5 ft.).
Where an open court is provided, the court shall have the following minimum dimensions:
TABLE K § 503.8: MINIMUM COURT DIMENSIONS
Type of Structure | Minimum Width Open Court | Minimum Width Closed Court | Minimum Area Closed Court |
Residential (except hotel): | 4 in./ft. of height of court; 10 ft. minimum. | 4 in./ft. of height of court; 15 ft. minimum. | Twice the square of the required width of court dimension; 350 sq. ft. minimum. |
Non-Residential and Lodging: | 2.5 in./ft. of height of court; 6 ft. minimum. | 2.5 in./ft. of height of court; 12 ft. minimum. | Twice the square of the required width of court dimension; 250 sq. ft. minimum. |
In the case of an alteration affecting the amount of light and ventilation required in an existing building in an R, RF, or RA zone by other municipal law or regulation, no legally required window shall be permitted to open onto a court that does not comply with the dimensions given in Subtitle K § 503.8.
The minimum required GAR for the CG-3 zone shall be 0.25.
D.C. Mun. Regs. tit. 11, r. 11-K503