Except as provided in this section and in Chapters 17 and 20 through 25 of this title, the height of a building or structure, not including a penthouse, in a Commercial District shall not exceed that set forth in the following table:
ZONE DISTRICT | MAXIMUM HEIGHT (Feet) | MAXIMUM HEIGHT (Stories) |
C-1 | 40 | 3 |
C-2-A | 50 | No Limit |
C-2-B,C-3-A | 65 | No Limit |
C-3-B | 70 | 6 |
C-2-B-1 | 75 | No Limit |
C-2-C,C-3-C | 90 | No Limit |
C-4 | 110 | No Limit |
C-5(PAD) | 130 | No Limit |
The height of buildings or structures specified in § 770.1 may be exceeded in the instances provided in §§ 770.3 through 770.9.
Spires, towers, domes, pinnacles or minarets serving as architectural embellishments, penthouses, ventilator shafts, antennas, chimneys, smokestacks, or fire sprinkler tanks may be erected to a height in excess of that which this sections otherwise authorizes. This section shall not be interpreted to bypass otherwise required special exception reviews.
In the C-4 District, a building or other structure may be erected to a height not exceeding one hundred thirty feet (130 ft.); provided, that the building or other structure shall face or abut a street not less than one hundred ten feet (110 ft.) wide between building lines.
In the C-5 (PAD) District, a building or other structure may be erected to a height not exceeding one hundred sixty feet (160 ft.); provided:
A penthouse may be erected to a height in excess of that which this section otherwise authorizes but shall not exceed the height, as measured from the surface of the roof upon which the penthouse is located, in the following table:
ZONE DISTRICT | MAXIMUM PENTHOUSE HEIGHT | MAXIMUM PENTHOUSE STORIES |
C-1, C-2-A | 12 ft. except 15 ft. for penthouse mechanical space | 1; second story permitted for penthouse mechanical space |
C-2-B, C-3-A | 12 ft. except 18 ft. 6 in. for penthouse mechanical space | 1; second story permitted for penthouse mechanical space |
C-2-B-1, C-3-B | 20 ft. | 1; second story permitted for penthouse mechanical space |
C-2-C; C-3-C; C-4; C-5 | 20 ft. | 1 plus mezzanine; second story permitted for penthouse mechanical space |
[REPEALED]
[REPEALED]
The height permitted for a building eligible for the additional density permitted pursuant to § 771.4 shall be that permitted by the Act to Regulate the Height of Buildings in the District of Columbia, approved June 1, 1910 (36 Stat. 452, as amended; D.C. Official Code §§ 6-601.01 to 6-601.09) .
D.C. Mun. Regs. tit. 11, r. 11-770