7 Del. Admin. Code § 1117-6.0

Current through Register Vol. 28, No. 1, July 1, 2024
Section 1117-6.0 - Data Reduction

Owners or operators of affected facilities shall use the following procedures for converting monitoring data to units of the standard where necessary.

6.1 For fuel burning equipment the procedures to be used to convert gaseous emission monitoring data to units of the standard, where necessary, shall be those set forth in paragraphs 5.1.1, 5.1.2 and 5.1.3 of Appendix P, 40 CFR Part 51 dated July 1, 1982, which are hereby adopted by reference with the word or phrase substitutions "Regulation" for "Appendix", "subsection numbers" for "subparagraph", and "3.1.4 of this regulation" for "paragraph 2.1.4 of this Appendix". Factors F and Fc shall be determined by methods approved by the Secretary.
6.2 For sulfuric acid plants the owner or operator shall:

Report the average sulfur dioxide concentration (ppm), production rate (tons H2SO4 produced/day), and the SO2 emission rate (lbs. SO2/hour) whenever the one-hour average exceeds the applicable standard of 2.1 of 7 DE Admin. Code 1109. For excess SO2 emissions lasting for more than three consecutive hours, the owner or operator shall summarize the data. The data shall be reported to the Department at the end of each calendar quarter.

01/11/1993

7 Del. Admin. Code § 1117-6.0