7 Del. Admin. Code § 1117-4.0

Current through Register Vol. 28, No. 1, July 1, 2024
Section 1117-4.0 - Performance Specifications
4.1 Any person who installs monitoring equipment to comply with this regulation shall demonstrate compliance with performance specifications set forth in Appendix B, 40 CFR Part 60, dated July 1, 1982, which are hereby adopted by reference:
4.1.1 For measuring opacity; Performance Specification 1;
4.1.2 For measuring NO or NOx; Performance Specification 2;
4.1.3 For measuring SO2; Performance Specification 2;
4.1.4 For measuring oxygen; Performance Specification 3;
4.1.5 For measuring carbon dioxide; Performance Specification 3.
4.2 Calibration gases and cycling time in continuous monitoring systems shall comply with the requirements set forth in paragraphs 3.3 and 3.4 of Appendix B in 40 CFR Part 51, dated July 1, 1982, which are hereby adopted by reference.
4.3 Zero and span drift in continuous monitoring systems shall comply with the requirements set forth in paragraphs 3.7 and 3.8 of Appendix P, 40 CFR Part 51, dated July 1, 1982, which are hereby adopted by reference.
4.4 Analytical Reference Methods 3.6 and 7 in 40 CFR Part 60, Appendix A dated July 1, 1982, are hereby adopted by reference.
4.5 Alternative procedures and requirements for continuous monitoring systems may be submitted for Department approval for the situations set forth in paragraph 3.9.1, 3.9.2, 3.9.3, 3.9.4, 3.9.5 and paragraphs 6.1 through 6.4 of Appendix P, 40 CFR Part 51, dated July 1, 1982, which are hereby adopted by reference with the word substitutions "Department" for "State" and "Regulation" for "Appendix." The Department approves the alternative data reduction procedures using wet basis pollutant and oxygen data set forth in paragraphs a and b in the Federal Register, Volume 41, Number 198, dated Tuesday, October 12, 1976.
4.6 Exemptions
4.6.1 Any source which has purchased an emission monitoring system or systems prior to September 11, 1974, may be exempt from meeting such test procedures prescribed in this regulation for a period not to exceed five years from plan approval or promulgation.
4.6.2 Any source which is regulated under 7 DE Admin. Code1120, New Source Performance Standards, shall be exempt from this regulation.
4.6.3 Any source which is regulated under 7 DE Admin. Code 1124, Control of Volatile Organic Compound Emissions, shall be exempt from the provisions of this regulation, except for 7.0 of this regulation.
4.7 Monitor Location - Any person who is required to install continuous monitoring systems or monitoring devices pursuant to this regulation shall install such systems or devices such that representative measurements of emissions or process parameters (i.e., oxygen, or carbon dioxide) from the affected facility are obtained.
4.8 Combined Effluents - When the effluents from two or more affected facilities of similar design and operating characteristics are combined before being released to the atmosphere, the owner or operator may install, as determined by the Department, monitoring systems on the combined effluent. When the affected facilities are not of similar design or operating characteristics, or when the effluent from one affected facility is released to the atmosphere through more than one point, the owner or operator may with prior written approval of the Department establish alternative procedures to implement the intent of these requirements.

07/17/1984

7 Del. Admin. Code § 1117-4.0