Section 30D-4.0 - Determination of VOC Content of Fugitive Emissions
4.1 Analysis Duration. Measure the VOC responses at each fugitive emission point during the entire test run or, if applicable, while the process is operating. If there are multiple emission locations, design a sampling system to allow a single FIA to be used to determine the VOC responses at all sampling locations.
4.2 Gas VOC Concentration.
4.2.1 Assemble the sample train. Calibrate the FIA and conduct a system check according to the procedures in 5.1 and 5.3 of this method, respectively.
4.2.2 Install the sample probe so that the probe is centrally located in the stack, pipe, or duct, and is sealed tightly at the stack port connection.
4.2.3 Inject zero gas at the calibration valve assembly. Allow the measurement system response to reach zero. Measure the system response time as the time required for the system to reach the effluent concentration after the calibration valve has been returned to the effluent sampling position.
4.2.4 Conduct a system check before, and a system drift check after, each sampling run according to the procedures in 5.2 and 5.3 of this method. If the drift check following a run indicates unacceptable performance (see 5.3 of this method), the run is not valid. The tester may elect to perform system drift checks during the run not to exceed one drift check per hour.
4.2.5 Verify that the sample lines, filter, and pump temperatures are 120 ± 5°C.
4.2.6 Begin sampling at the start of the test period and continue to sample during the entire run. Record the starting and ending times and any required process information, as appropriate. If multiple emission locations are sampled using a single FIA, sample at each location for the same amount of time (e.g., two min.) and continue to switch from one location to another for the entire test run. Be sure that total sampling time at each location is the same at the end of the test run. Collect at least four separate measurements from each sample point during each hour of testing. Disregard the response measurements at each sampling location until two times the response time of the measurement system has elapsed. Continue sampling for at least one minute and record the concentration measurements.
4.3 Background Concentration.
4.3.1 Locate all NDO's of the TTE. A sampling point shall be at the center of each NDO, unless otherwise approved by the Department. If there are more than six NDO's, choose six sampling points evenly spaced among the NDO's.
4.3.2 Assemble the sample train. Calibrate the FIA and conduct a system check according to the procedures in 5.1 and 5.3 of this method.
4.3.3 Position the probe at the sampling location.
4.3.4 Determine the response time, conduct the system check, and sample according to the procedures described in 4.2.3 through 4.2.6 of this method.
4.4 Alternative Procedure. The direct interface sampling and analysis procedure described in Section 7.2 of Method 18 may be used to determine the gas VOC concentration (see 1.1 of Appendix E of this regulation). The system must be designed to collect and analyze at least one sample every 10 minutes.