Section 30E-3.0 - Determination of Volumetric Flow Rate of Fugitive Emissions
3.1 Preliminary Determinations. To determine which exhaust points should be measured for volumetric flow rates and VOC concentrations, the following procedure shall be used:
3.1.1 Forced Draft Openings. Identify all forced draft openings. Determine the volumetric flow rate according to Method 2.
3.1.2 The NDO's Exhaust Points. The NDO's in the roof of a facility are considered to be exhaust points. Determine volumetric flow rate from these NDO's. Divide the cross-sectional area according to Method 1 using 12 equal areas. Use the appropriate velocity measurement devices (e.g., propeller anemometers).
3.1.3 Other NDO's.
3.1.3.1 This step is optional. Determine the exhaust flow rate, including that of the control device, from the enclosure and the intake air flow rate. If the exhaust flow rate divided by the intake air flow rate is greater than 1.1, then all other NDO's are not considered to be significant exhaust points. It is not necessary to measure the volumetric flow rate and VOC concentration from these insignificant exhaust points during the CE test.
3.1.3.2 If the option above is not taken, identify all other NDO's and other potential points through which fugitive emissions may escape the enclosure; then use the following criteria to determine whether flow rates and VOC concentrations need to be measured.
3.1.3.2.1 Using the appropriate flow direction indicator, determine the flow direction. An NDO with zero or inward flow is not an exhaust point.
3.1.3.2.2 Measure the outward volumetric flow rate from the remainder of the NDO's. If the collective flow rate is 2% or less of the flow rate from 3.1.1 and 3.1.2 of this method, then these NDO's, except those within two equivalent diameters (based on NDO opening) from VOC sources, may be considered to be non-exhaust points.
3.1.3.2.3 If the percentage calculated in 3.1.3.2.2 of this method is greater than 2%, those NDO's (except those within two equivalent diameters from VOC sources) whose volumetric flow rates total 2% of the flow rate from 3.1.1 and 3.1.2 of this method may be considered as non-exhaust points. All remaining NDO's shall be measured for volumetric flow rate and VOC concentrations during the CE test.
3.1.3.2.4 The tester may choose to measure VOC concentrations at the forced exhaust points and the NDO's. If the total VOC emissions from the non-roof NDO's are less than 2% of the emissions from the forced draft and roof NDO's, then it is not necessary to measure the VOC concentration at the non-roof NDO's during the CE test.
3.2 Determination of Flow Rates.
3.2.1 Measure the volumetric flow rate at all locations identified as exhaust points in 3.1 in this method. Divide each exhaust opening into nine equal areas for rectangular openings and into eight equal areas for circular openings.
3.2.2 Measure the velocity at each site at least once every hour during each sampling run using Method 2 or 2A, if applicable, or using the low velocity instruments in 2.2.2 in this method.