Section 1124-A-G-10.0 - Quality assurance
10.1 The owner or operator shall assure proper calibration, maintenance, and operation of the continuous emissions monitoring system on a continual basis.
10.2 The owner or operator shall establish a quality assurance program to evaluate and monitor performance on a continual basis. The following checks shall be done routinely:
10.2.1 A daily calibration check for each monitor. The calibration shall be adjusted if the check indicates the instrument's calibration drift exceeds the specification established in 6.0 of this appendix.
10.2.2 A daily system audit that includes the following:
10.2.2.1 A review of the calibration check data.
10.2.2.2 An inspection of the recording system.
10.2.2.3 An inspection of the control panel warning lights.
10.2.2.4 An inspection of the sample transport/interface system (e.g., flowmeters, filters), as appropriate.
10.2.3 A quarterly calibration error test at the span midpoint.
10.2.4 The entire performance specification test repeated every second year.