7 Del. Admin. Code § app G § 1124-A-G-1.0

Current through Register Vol. 28, No. 3, September 1, 2024
Section 1124-A-G-1.0 - Applicability
1.1 This method applies to the measurement of total hydrocarbons as a surrogate measure for the total gaseous organic concentration of the VOC control device outlet. The concentration is expressed in terms of propane.
1.2 The Department may approve the use of gas conditioning, including cooling to between 4.4 and 18°C (40° and 64°F), and condensate traps to reduce the moisture content of the sample gas if the owner/operator:
1.2.1 Successfully demonstrates to the Department that the use of such system is necessary for the specific application.
1.2.2 Includes in the demonstration a quantification of the total hydrocarbon concentration (THC) lost to the gas conditioning system.

7 Del. Admin. Code § app G § 1124-A-G-1.0