Current through Register Vol. 28, No. 7, January 1, 2025
Section 6-303.11 - IntensityThe light intensity shall be:
(A) At least 108 lux (10 foot candles) at a distance of 75 cm (30 inches) above the floor, in walk-in refrigeration units and dry FOOD storage areas and in other areas and rooms during periods of cleaning;(B) At least 215 lux (20 foot candles): (1) At a surface where food is provided for consumer self-service such as buffets and salad bars or where fresh produce or PACKAGED FOODS are sold or offered for consumption,(2) Inside equipment such as reach-in and under-counter refrigerators; and(3) At a distance of 75 cm (30 inches) above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms; and(C) At least 540 lux (50 foot candles) at a surface where a FOOD EMPLOYEE is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor.16 Del. Admin. Code § 6-303.11
17 DE Reg. 1084( 5/1/2014) (Final)