Section 4-501.114 - Manual and Mechanical Warewashing Equipment, Chemical Sanitization -Temperature, pH, Concentration, and Hardness

A chemical SANITIZER used in a SANITIZING solution for a manual or mechanical operation at contact times specified under 1(4-703.11 (C) shall meet the criteria specified under ¶ § 7-204.11 Sanitizers, Criteria, shall be used in accordance with the EPA-registered label use instructions,p and shall be used as follows:

(A) A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart;p

Concentration Range (MG/L) Minimum Temperature pH 10 or less °C (°F) Minimum Temperature pH 8 or less °C (°F)
25-49 49(120) 49(120)
50-99 38(100) 24 (75)
100 13(55) 13(55)

(B) An iodine solution shall have a:
(1) Minimum temperature of 20°C (68°F),P
(2) pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies the solution is effective, p and
(3) Concentration between 12.5 mg/L and 25 mg/L; p
(C) A quaternary ammonium compound solution shall:
(1) Have a minimum temperature of 24°C (75°F), p
(2) Have a concentration as specified under § 7-204.11 and as indicated by the manufacturer's use directions included in the labeling, p and
(3) Be used only in water with 500 mg/L hardness or less or in water having a hardness no greater than specified by the EPA-registered label use instructions; p
(D) If another solution of a chemical specified under ¶¶ (A) -(C) of this section is used, the PERMIT HOLDER shall demonstrate to the REGULATORY AUTHORITY that the solution achieves SANITIZATION and the use of the solution shall be APPROVED;p
(E) If a chemical SANITIZER other than chlorine, iodine, or a quaternary ammonium compound is used, it shall be applied in accordance with the EPA-registered label use instructions; pand
(F) If a chemical SANITIZER is generated by a device located on-site at the FOOD ESTABLISHMENT it shall be used as specified in ¶¶(A) - (D) of this section and shall be produced by a device that:
(1) Complies with regulation as specified in §§ 2(q)(1) and 12 of the Federal Insecticide, Fungicide, and RodenticideAct(FIFRA),p
(2) Complies with 40 CFR 152.500 Requirement for Devices and 40 CFR 156.10 Labeling Requirements, p
(3) Displays the EPA device manufacturing facility registration number on the device,Pf and
(4) Is operated and maintained in accordance with manufacturer's instructions pf.