Current through Register Vol. 28, No. 5, November 1, 2024
Section 706-7-3.0 - Egress3.1 Occupant Load: The occupancy shall be limited to 25 persons, regardless if an attendant or a patron.3.2 Exits 3.2.1 There shall be a minimum of at least two exits from each floor or level. A window that leads to a 4-foot by 4-foot landing with a stairway shall be permitted.3.2.2 All exits doors shall swing in the direction of exit travel.3.2.3 Maximum travel distance from all areas of the building to an exit shall not exceed 75 feet.3.3 Illumination: The State Fire Marshal may require on a case by case basis additional means for normal illumination.3.4 Emergency Lighting: Emergency lighting shall be provided so that the floor level of all areas able to be occupied by the public is provided with minimum lighting in the event of loss of normal power3.5 Exit Marking: All exits shall be provided with conspicuous, internally or externally illuminated standard EXIT signs. The exit signs shall also be provided to be illuminated in the emergency lighting mode so as to be readily visible even in the event of loss of normal power.1 Del. Admin. Code § 706-7-3.0