Conn. Agencies Regs. § 16-50j-95

Current through May 9, 2024
Section 16-50j-95 - Considerations for decision

In making its decision to grant or deny an application for a certificate or to issue or not to issue a petition for a declaratory ruling, the Council shall, consistent with the Uniform Administrative Procedure Act, Chapter 54 of the Connecticut General Statutes, and the Public Utility Environmental Standards Act, Chapter 277a of the Connecticut General Statutes, consider, among other relevant facts and circumstances, the following factors:

(a)Setback Distances.
(1)Requirements.
(A) Any application for a certificate for a proposed wind turbine facility with a capacity of more than 65 megawatts shall include setback distances from each of the proposed wind turbine locations and any alternative wind turbine locations of not less than 2.5 times the wind turbine height from all property lines at the proposed site and any alternative sites or shall comply with the wind turbine manufacturer's recommended setback distances, whichever is greater. A copy of the wind turbine manufacturer's recommended setback distances shall be included in the application or petition. In its discretion, the Council may require greater setback distances based on the results of any evaluation report submitted under Section 16-50j-94 of the Regulations of Connecticut State Agencies.
(B) Any petition for a declaratory ruling for a proposed wind turbine facility with a capacity of less than 65 megawatts shall include setback distances from each of the proposed wind turbine locations and any alternative wind turbine locations of not less than 1.5 times the wind turbine height from all property lines at the proposed site and any alternative sites or shall comply with the wind turbine manufacturer's recommended setback distances, whichever is greater. A copy of the wind turbine manufacturer's recommended setback distances shall be included in the application or petition. In its discretion, the Council may require greater setback distances based on the results of any evaluation report submitted under Section 16-50j-94 of the Regulations of Connecticut State Agencies.
(2)Waiver of requirements. The minimum required setback distances for each of the proposed wind turbine locations and any alternative wind turbine locations at the proposed site and any alternative sites may be waived, but in no case shall the setback distance from the proposed wind turbines and any alternative wind turbines be less than the manufacturer's recommended setback distances from any occupied residential structure or less than 1.5 times the wind turbine height from any occupied residential structure, whichever is greater:
(A) by submission to the Council of a written agreement between the applicant or petitioner and abutting property owners of record stating that consent is granted to allow reduced setback distances; or
(B) by a vote of two-thirds of the Council members present and voting to waive the minimum required setback distances upon a showing of good cause, which includes consideration of:
(i) land uses and land use restrictions on abutting parcels;
(ii) public health and safety;
(iii) public benefit and reliability;
(iv) environmental impacts;
(v) policies of the state; and
(vi) wind turbine design and technology.
(b)Noise.

Noise levels generated by the operation of each of the proposed wind turbines and any alternative wind turbines at the proposed site and any alternative sites shall comply with the Department of Energy and Environmental Protection Noise Control Regulations under Sections 22a-69-1 to 22a-69-7, inclusive, of the Regulations of Connecticut State Agencies.

(c)Shadow Flicker.
(1)Requirements. Shadow flicker shall not occur more than 30 total annual hours cumulative at any off-site occupied structure location from each of the proposed wind turbine locations and any alternative wind turbine locations at the proposed site and any alternative sites.
(2)Waiver of Requirements. The maximum total annual hours of shadow flicker generated by the operation of each of the proposed wind turbines and any alternative wind turbines at the proposed site and any alternative sites may be waived:
(A) by submission to the Council of a written agreement between the applicant or petitioner and property owners of record stating that consent is granted to allow excess total annual hours of shadow flicker; or
(B) by a vote of two-thirds of the Council members present and voting to waive the total annual hours of shadow flicker requirements upon a showing of good cause, which includes consideration of:
(i) land uses and land use restrictions on abutting parcels;
(ii) public health and safety;
(iii) public benefit and reliability;
(iv) environmental impacts;
(v) policies of the state; and
(vi) wind turbine design and technology.

Conn. Agencies Regs. § 16-50j-95

Effective May 9, 2014