2 Colo. Code Regs. § 404-1-611

Current through Register Vol. 47, No. 20, October 25, 2024
Section 2 CCR 404-1-611 - AIR AND GAS DRILLING
a. Drilling compressors (air or gas) will be located at least 125 feet from the wellbore and in a direction away from the air or gas discharge line.
b. The air or gas discharge line will be laid in as nearly a straight line as possible from the wellbore and be a minimum of 150 feet in length. The line will be securely anchored.
c. A pilot flame will be maintained at the end of the air or gas discharge line at all times when air, gas, or mist drilling, or Well testing is in progress.
d. All combustible material will be kept at least 100 feet away from the air and gas discharge line and Flare Pit.
e. The air line from the compressors to the standpipe will be of adequate strength to withstand at least the maximum discharge pressure of the compressors used, and will be checked daily for any evidence of damage or weakness.

2 CCR 404-1-611

37 CR 16, August 25, 2014, effective 9/30/2014
38 CR 01, January 10, 2015, effective 2/14/2015
38 CR 03, February 10, 2015, effective 3/2/2015
38 CR 07, April 10, 2015, effective 4/30/2015
38 CR 16, August 25, 2015, effective 9/14/2015
39 CR 04, February 25, 2016, effective 3/16/2016
41 CR 05, March 10, 2018, effective 4/1/2018
41 CR 06, March 25, 2018, effective 5/1/2018
41 CR 23, December 10, 2018, effective 12/30/2018
42 CR 02, January 25, 2019, effective 2/14/2019
42 CR 17, September 10, 2019, effective 9/30/2019
42 CR 24, December 25, 2019, effective 1/14/2020
43 CR 17, September 10, 2020, effective 9/30/2020
43 CR 13, July 10, 2020, effective 11/2/2020
43 CR 24, December 25, 2020, effective 1/15/2021
45 CR 07, April 10, 2022, effective 4/30/2022
45 CR 09, May 10, 2022, effective 5/30/2022
45 CR 13, July 10, 2022, effective 7/30/2022