Current through Register Vol. 47, No. 24, December 25, 2024
Section 7 CCR 1101-17-3-2 - Retail Motor Fuel Dispensers Inspection and Testing(a) All retail motor fuel dispensers (RMFDs) shall be suitable for their intended use, properly installed, accurate and maintained in that condition by their owner/operator.(b) All RMFDs shall have an active certificate of conformance (CC) from either the National Type Evaluation Program (NTEP) or the California Type Evaluation Program (CTEP) prior to installation or use for commercial purposes.(c) All RMFDs shall be capable of displaying delivered quantity in units of mass and all adjustments and calibrations of RMFDs shall be made utilizing mass measurement standards.(d) The Division shall be notified when any new or remanufactured RMFD is placed in service at a new or existing installation.(1) Notification shall be submitted using a placed in service report provided by the Division.(e) No owner/operator of any RMFD shall use the RMFD for the measurement of hydrogen unless it has been proved in a manner acceptable to the Division and sealed as correct by a state inspector or registered service agency (RSA).(1) All RMFDs shall be proved and sealed as correct on an annual basis by either a state inspector or RSA.(f) Means shall be provided at the hydrogen fueling facility to return all hydrogen product used for proving meters back to the storage equipment or the facility's hydrogen vent system when proving is completed.(g) If any RMFD fails to comply with any of the provisions of this regulation, a state inspector shall seal it in such a manner as to prohibit its use and it shall remain sealed until it complies with all of the provisions of this regulation. (1) When an RMFD is brought back into compliance with this regulation, it must be placed back in service by a state inspector or RSA.(h) All RMFDs shall comply with the minimum standards as prescribed by the applicable sections of the codes incorporated by this regulation except as modified or rejected by this regulation or by the Division.39 CR 18, September 25, 2016, effective 1/1/2017