Current through Register Vol. 47, No. 22, November 25, 2024
Section 5 CCR 1003-2-100.6 - RECLAIMED WATER AND GRAYWATER TREATMENT FACILITY AND DISTRIBUTION SYSTEM CLASSIFICATION100.6.1 Reclaimed water treatment facilities or a graywater treatment works with a capacity greater than 2,000 gpd in Graywater Control Regulation, 5 CCR 1002-86, shall be based on the water treatment facility classifications in section 100.4 and the domestic wastewater treatment facility classifications in section 100.5 as noted below. The facilities may require single or dual classifications based on the site-specific conditions. (a) Facilities that receive untreated wastewater or graywater shall be classified in accordance with the domestic wastewater treatment facility classifications in section 100.5.(b) Facilities that discharge for indoor non-potable plumbing uses or direct potable water uses shall be classified in accordance with the water treatment facility classifications in section 100.4.(c) Facilities that receive treated effluent from a separate wastewater treatment facility, either domestic or industrial, may be classified in accordance with the water treatment facility classifications in section 100.4, provided the treatment technologies used at the reclaimed water treatment facilities are included in section 100.4. Alternatively, these facilities may be classified in accordance with the domestic wastewater treatment facility classifications in section 100.5, provided the treatment technologies used at the reclaimed water treatment facilities are included in section 100.5.100.6.2 Reclaimed water distribution systems beyond the property of the owner of the reclaimed water treatment facility that are operated by 1) reclaimed water treaters or 2) reclaimed water users with indoor uses at multiple buildings or users with booster chlorine facilities; and 3) distribution pipes associated with a "category D non-single family, indoor toilet and urinal flushing graywater treatment works" in Graywater Control Regulation, 5 CCR 1002-86, that extend beyond the building with the graywater treatment facility; shall be classified based on the water distribution facility classifications in section 100.8 using the following flow table for Step 1 rather than the population table. Step 1 Reclaimed Water Distribution Table
CLASS | RECLAIMED WATER DISTRIBUTED PER DAY (MGD) |
Class 1 | Less than 0.3 |
Class 2 | 0.31 - 2.5 |
Class 3 | 2.51 - 10.0 |
Class 4 | Over 10.0 |
37 CR 18, September 25, 2014, effective 10/30/201438 CR 14, July 25, 2015, effective 8/30/201539 CR 01, January 10, 2016, effective 1/30/201639 CR 24, December 25, 2016, effective 1/30/201740 CR 14, July 25, 2017, effective 8/31/201741 CR 20, October 25, 2018, effective 3/1/201941 CR 24, December 25, 2018, effective 3/1/201942 CR 24, December 25, 2019, effective 1/14/202043 CR 21, November 10, 2020, effective 11/30/202044 CR 05, March 10, 2021, effective 3/31/202144 CR 09, May 10, 2021, effective 5/30/202144 CR 20, October 25, 2021, effective 11/30/202147 CR 06, March 25, 2024, effective 4/15/2024