For municipal, domestic and industrial dischargers, the monthly and annual wasteloads shall be determined as follows:
Monthly Phosphorus Load (Pounds) = Monthly volume discharged (million gallons) x average of all individual concentration values for that month (mg/l) x 8.34
Monthly Volume Discharged (Million Gallons)(MG) = Volume in all lysimeters (gallons) x Area of land application site (square feet) / Total Area of all lysimeters (square feet) (1,000,000 gal/mg)
Phosphorus Concentration (mg/l) = the sum of the total phosphorus concentrations of all samples (mg/l) for the month / the number of samples collected.
Flow-Weighted Phosphorus Concentration (mg/l) = sum of the products of phosphorus concentrations and monthly volumes for each lysimeter / the sum of all monthly volumes for all lysimeters.
Monthly Average Phosphorus Concentration = the sum of all concentration values for a lysimeter for the month / the number of concentration values for that lysimeter.
5 CCR 1002-74.4