Current through Register Vol. 47, No. 22, November 25, 2024
Section 5 CCR 1001-10-B-VI - Use of Asbestos in the Manufacturing, Commerce and Construction IndustriesVI.A. Standard for Asbestos Mills Each owner or operator of an asbestos mill shall discharge no visible emissions to the ambient air from the asbestos mill and use the methods specified by Section III.J.1. (Air Cleaning and Negative Pressure Requirements) to clean emissions containing particulate asbestos material before they escape to, or are vented to, the ambient air.
VI.B. Standard for Road Ways No owner or operator of a roadway may deposit asbestos tailings or asbestos-containing waste material on that roadway, unless it is a temporary roadway on an area of asbestos ore deposits.
VI.C. Standard for Manufacturing VI.C.1. Applicability: This section applies to the following manufacturing operations using commercial asbestos. VI.C.1.a. The manufacture of cloth, cord, wicks, tubing, tape, twine, rope, thread, yarn, roving, lap, or other textile materials.VI.C.1.b. The manufacture of cement products.VI.C.1.c. The manufacture of fireproofing and insulating materials.Vl.C.1.d. The manufacture of friction products.VI.C.1.e. The manufacture of paper, millboard, and felt.VI.C.1.f. The manufacture of floor tile.VI.C.1.g. The manufacture of paints, coatings, caulks, adhesives, and sealants.VI.C.1.h. The manufacture of plastics and rubber materials.VI.C.1.i. The manufacture of chlorine utilizing asbestos diaphragm technology.VI.C.1.j. The manufacture of shotgun shell wads.VI.C.1.k. The manufacture of asphalt concrete.VI.C.2. Standard: Each owner or operator of any of the manufacturing operations to which this Section VI.C. (Standards for Manufacturing) applies shall: VI.C.2.a. Discharge no visible emissions to the ambient air from these operations or from any building or structure in which they are conducted; andVI.C.2.b. Use the methods specified in Section III.J.1. (Air Cleaning and Negative Pressure Requirements) to clean emissions from these operations containing particulate asbestos material before they escape to, or are vented to, the ambient air.VI.D. Standard for Spraying The owner or operator of an operation in which asbestos-containing materials are spray applied shall comply with the following requirements:
VI.D.1. Use materials that contain one percent asbestos or less on a dry weight basis for spray-on application on buildings, structures, pipes, and conduits, except as provided in Section VI.D.1.b., and:VI.D.1.a. Notify the Division at least 20 days before beginning the spraying operation. Include the following information in the notice: VI.D.1.a.(i) Name and address of owner or operator.VI.D.1.a.(ii) Location of spraying operation.VI.D.1.a.(iii) Procedures to be followed to meet the requirements of Section VI.D. (Standard for Spraying).VI.D.1.b. Discharge no visible emissions to the ambient air from the spray-on application of the asbestos-containing material and/or use the methods specified by Section III.J.1. (Air Cleaning and Negative Pressure Requirements) to clean emissions containing particulate asbestos material before they escape to, or are vented to, the ambient air.VI.D.2. The requirements of Section VI.D.1.a. do not apply to the spray-on application of materials where the asbestos fibers in the materials are encapsulated with a bituminous or resinous binder during spraying and the materials are not friable after drying.VI.E. STANDARD FOR FABRICATING VI.E.1. Applicability. This section applies to the following fabricating operations using commercial asbestos: VI.E.1.a. The fabrication of cement building products.VI.E.1.b. The fabrication of friction products, except those operations that primarily install asbestos friction materials on motor vehicles.VI.E.1.c. The fabrication of cement or silicate board for ventilation hoods; ovens; electrical panels; laboratory furniture; bulkheads, partitions, and ceilings for marine construction; and flow control devices for the molten metal industry.VI.E.2. Standard. Each owner or operator of any of the fabricating operations to which this Section VI.E. (Standard for Fabricating) applies shall:VI.E.2.a. Discharge no visible emissions to the ambient air from any of the operations or from any building or structure in which they are conducted; andVI.E.2.b. Use the methods specified by Section III.J.1. (Air Cleaning and Negative Pressure Requirements) to clean emissions containing particulate asbestos material before they escape to, or are vented to, the ambient air.VI.F. Standard for Insulating Materials No owner or operator of a facility may install or reinstall on a facility component any insulating materials that contain commercial asbestos if the materials are either molded and friable or wet-applied and friable after drying. The provisions of this subsection do not apply to spray-applied insulating materials regulated under Section VI.D. (Standard for Spraying).
37 CR 18, September 25, 2014, effective 10/15/201438 CR 05, March 10, 2015, effective 3/30/201538 CR 18, September 25, 2015, effective 10/15/201539 CR 18, September 25, 2016, effective 10/15/201640 CR 12, June 25, 2017, effective 7/15/201741 CR 11, June 10, 2018, effective 6/30/201842 CR 16, August 25, 2019, effective 9/14/201943 CR 03, February 10, 2020, effective 1/16/202043 CR 03, February 10, 2020, effective 3/1/202043 CR 12, June 25, 2020, effective 7/15/202044 CR 04, February 25, 2021, effective 3/17/202144 CR 12, June 25, 2021, effective 7/15/202145 CR 12, June 25, 2022, effective 7/15/202246 CR 12, June 25, 2023, effective 7/15/202347 CR 12, June 25, 2024, effective 7/15/2024