6 Colo. Code Regs. § 1007-1-19.12

Current through Register Vol. 47, No. 11, June 10, 2024
Section 6 CCR 1007-1-19.12 - Control of source movement
19.12.1 The mechanism that moves the sources of a panoramic irradiator must require a key to actuate.
19.12.1.1 Actuation of the mechanism must cause an audible signal to indicate that the sources are leaving the shielded position.
19.12.1.2 Only one key may be in use at any time, and only operators or facility management may possess it.
19.12.1.3 The key must be attached to a portable radiation survey meter by a chain or cable.
19.12.1.4 The lock for source control must be designed so that the key may not be removed if the sources are in an unshielded position.
19.12.1.5 The door to the radiation room must require the same key.
19.12.2 The console of a panoramic irradiator must have a source position indicator that indicates when the sources are in the fully shielded position, when they are in transit, and when the sources are exposed.
19.12.3 The control console of a panoramic irradiator must have a control that promptly returns the sources to the shielded position.
19.12.4 Each control for a panoramic irradiator must be clearly marked as to its function.

6 CCR 1007-1-19.12

Colorado Register, Vol 37, No. 14. July 25, 2014, effective 8/14/2014
38 CR 02, January 25, 2015, effective 2/14/2015
38 CR 05, March 10, 2015, effective 3/30/2015
38 CR 12, June 25, 2015, effective 7/15/2015
38 CR 14, July 25, 2015, effective 8/14/2015
39 CR 02, January 25, 2016, effective 2/14/2016
39 CR 16, August 25, 2016, effective 9/14/2016
39 CR 22, November 25, 2016, effective 12/15/2016
40 CR 11, June 10, 2017, effective 6/30/2017
40 CR 20, October 25, 2017, effective 11/14/2017
42 CR 24, December 25, 2019, effective 1/14/2020
43 CR 14, July 25, 2020, effective 8/14/2020
43 CR 18, September 25, 2020, effective 10/15/2020
44 CR 11, June 10, 2021, effective 7/15/2021
44 CR 14, July 25, 2021, effective 8/14/2021
45 CR 22, November 25, 2022, effective 12/15/2022