6 Colo. Code Regs. § 1007-1-7M

Current through Register Vol. 47, No. 11, June 10, 2024
Appendix 6 CCR 1007-1-7M - TRAINING FOR USE OF REMOTE AFTERLOADER UNITS, TELETHERAPY UNITS, AND GAMMA STEREOTACTIC RADIOSURGERY UNITS

Except as provided in Appendix 7P, the licensee shall require an authorized user of a sealed source for a use authorized under 7.48 to be a physician who:

7M1 Is certified by a medical specialty board whose certification process has been recognized by the NRC or an Agreement State and who meets the requirements in 7M3. The names of board certifications that have been recognized by the NRC or an Agreement State are posted on the NRC's Medical Uses Licensee Toolkit web page. To have its certification process recognized, a specialty board shall require all candidates for certification to:

7M1.1 Successfully complete a minimum of 3 years of residency training in a radiation therapy program approved by the Residency Review Committee of the Accreditation Council for Graduate Medical Education or the Royal College of Physicians and Surgeons of Canada or the Council on Postdoctoral Training of the American Osteopathic Association;

and

7M1.2 Pass an examination, administered by diplomates of the specialty board, which tests knowledge and competence in radiation safety, radionuclide handling, treatment planning, quality assurance, and clinical use of stereotactic radiosurgery, remote afterloaders and external beam therapy;

or

7M2

7M2.1 Has completed a structured educational program in basic radionuclide techniques applicable to the use of a sealed source in a therapeutic medical unit that includes:

(1) 200 hours of classroom and laboratory training in the following areas:

(a) Radiation physics and instrumentation;

(b) Radiation protection;

(c) Mathematics pertaining to the use and measurement of radioactivity; and

(d) Radiation biology;

and

(2) 500 hours of work experience, under the supervision of an authorized user who meets the requirements in Appendix 7P, Appendix 7M, or equivalent Agreement State or NRC requirements at a medical facility that is authorized to use radioactive materials in 7.48, involving:

(a) Reviewing full calibration measurements and periodic spot checks;

(b) Preparing treatment plans and calculating treatment doses and times;

(c) Using administrative controls to prevent a medical event involving the use of radioactive material;

(d) Implementing emergency procedures to be followed in the event of the abnormal operation of the medical unit or console;

(e) Checking and using survey meters; and

(f) Selecting the proper dose and how it is to be administered;

and

7M2.2 Has completed 3 years of supervised clinical experience in radiation therapy, under an authorized user who meets the requirements in Appendix 7P, Appendix 7M, or equivalent Agreement State or NRC requirements, as part of a formal training program approved by the Residency Review Committee for Radiation Oncology of the Accreditation Council for Graduate Medical Education or the Royal College of Physicians and Surgeons of Canada or the Council on Postdoctoral Training of the American Osteopathic Association. This experience may be obtained concurrently with the supervised work experience required by 7M2.1(2);

and

7M2.3 Has obtained written attestation that the individual has satisfactorily completed the requirements in 7M2.1 and 7M2.2 and 7M3; and is able to independently fulfill the radiation safety-related duties as an authorized user of each type of therapeutic medical unit for which the individual is requesting authorized user status. The attestation must be obtained from either:

(1) A preceptor authorized user who meets the requirements in Appendix 7P, Appendix 7M, or equivalent Agreement State or NRC requirements for the type(s) of therapeutic medical unit for which the individual is requesting authorized user status;

or

(2) A residency program director who affirms in writing that the attestation represents the consensus of the residency program faculty where at least one faculty member is an authorized user who meets the requirements in Appendix 7P, Appendix 7M, or equivalent Agreement State or NRC requirements, for the type(s) of therapeutic medical unit for which the individual is requesting authorized user status, and concurs with the attestation provided by the residency program director. The residency training program must be approved by the Residency Review Committee of the Accreditation Council for Graduate Medical Education or the Royal College of Physicians and Surgeons of Canada or the Council on Postdoctoral Training of the American Osteopathic Association and must include training and experience specified in 7M2.1 and 7M2.2.

7M3 Has received training in device operation, safety procedures, and clinical use for the type(s) of use for which authorization is sought. This training requirement may be satisfied by satisfactory completion of a training program provided by the vendor for new users or by receiving training supervised by an authorized user or authorized medical physicist, as appropriate, who is authorized for the type(s) of use for which the individual is seeking authorization.

6 CCR 1007-1-7M

Colorado Register, Vol 37, No. 14. July 25, 2014, effective 8/14/2014
38 CR 02, January 25, 2015, effective 2/14/2015
38 CR 05, March 10, 2015, effective 3/30/2015
38 CR 12, June 25, 2015, effective 7/15/2015
38 CR 14, July 25, 2015, effective 8/14/2015
39 CR 02, January 25, 2016, effective 2/14/2016
39 CR 16, August 25, 2016, effective 9/14/2016
39 CR 22, November 25, 2016, effective 12/15/2016
40 CR 11, June 10, 2017, effective 6/30/2017
40 CR 20, October 25, 2017, effective 11/14/2017
42 CR 24, December 25, 2019, effective 1/14/2020
43 CR 14, July 25, 2020, effective 8/14/2020
43 CR 18, September 25, 2020, effective 10/15/2020
44 CR 11, June 10, 2021, effective 7/15/2021
44 CR 14, July 25, 2021, effective 8/14/2021
45 CR 22, November 25, 2022, effective 12/15/2022