6 Colo. Code Regs. § 1007-1-4.15

Current through Register Vol. 47, No. 11, June 10, 2024
Section 6 CCR 1007-1-4.15 - Compliance with Dose Limits for Individual Members of the Public
4.15.1 The licensee or registrant shall make or cause to be made surveys of radiation levels in unrestricted areas and radioactive materials in effluents released to unrestricted areas to demonstrate compliance with the dose limits for individual members of the public in 4.14.
4.15.2 A licensee or registrant shall show compliance with the annual dose limit in 4.14 by:
4.15.2.1 Demonstrating by measurement or calculation that the total effective dose equivalent to the individual likely to receive the highest dose from the licensed or registered operation does not exceed the annual dose limit; or
4.15.2.2 Demonstrating that:
(1) The annual average concentrations of radioactive material released in gaseous and liquid effluents at the boundary of the unrestricted area do not exceed the values specified in Table 4B2 of Appendix 4B; and
(2) If an individual were continually present in an unrestricted area, the dose from external sources would not exceed 0.02 mSv (0.002 rem) in an hour and 0.5 mSv (0.05 rem) in a year.
4.15.3 Upon approval from the Department, the licensee or registrant may adjust the effluent concentration values in Appendix 4B, Table 4B2, for members of the public, to take into account the actual physical and chemical characteristics of the effluents, such as, aerosol size distribution, solubility, density, radioactive decay equilibrium, and chemical form.
4.15.4 Rooms or areas in which diagnostic x-ray systems are the only source of radiation shall demonstrate compliance with 4.15.2.1 after construction of a new x-ray facility, after modification or renovation of an existing x-ray facility, or installation or a new x-ray machine in an existing x-ray facility when there is a change in primary beam orientation, or a change in primary shielding due to the modification or renovation of a facility, or where there is a projected increase in the x-ray workload from that which was used for a prior x-ray shielding design.
4.15.5 Rooms or areas in which only dental intraoral, dental panoramic, mini-c-arm x-ray, or bone densitometry systems are used, are exempt from the requirements of 4.15.2.1.

6 CCR 1007-1-4.15

Colorado Register, Vol 37, No. 14. July 25, 2014, effective 8/14/2014
38 CR 02, January 25, 2015, effective 2/14/2015
38 CR 05, March 10, 2015, effective 3/30/2015
38 CR 12, June 25, 2015, effective 7/15/2015
38 CR 14, July 25, 2015, effective 8/14/2015
39 CR 02, January 25, 2016, effective 2/14/2016
39 CR 16, August 25, 2016, effective 9/14/2016
39 CR 22, November 25, 2016, effective 12/15/2016
40 CR 11, June 10, 2017, effective 6/30/2017
40 CR 20, October 25, 2017, effective 11/14/2017
42 CR 24, December 25, 2019, effective 1/14/2020
43 CR 14, July 25, 2020, effective 8/14/2020
43 CR 18, September 25, 2020, effective 10/15/2020
44 CR 11, June 10, 2021, effective 7/15/2021
44 CR 14, July 25, 2021, effective 8/14/2021
45 CR 22, November 25, 2022, effective 12/15/2022