6 Colo. Code Regs. § 1007-1-4.9

Current through Register Vol. 47, No. 11, June 10, 2024
Section 6 CCR 1007-1-4.9 - Determination of Internal Exposure
4.9.1 For purposes of assessing dose used to determine compliance with occupational dose equivalent limits, the licensee or registrant shall, when required pursuant to 4.18, take suitable and timely measurements of:
4.9.1.1 Concentrations of radioactive materials in air in work areas; or
4.9.1.2 Quantities of radionuclides in the body; or
4.9.1.3 Quantities of radionuclides excreted from the body; or
4.9.1.4 Combinations of 4.9.1.1, 4.9.1.2 and 4.9.1.3.
4.9.2 Unless respiratory protective equipment is used, as provided in 4.24, or the assessment of intake is based on bioassays, the licensee or registrant shall assume that an individual inhales radioactive material at the airborne concentration in which the individual is present.
4.9.3 When specific information on the physical and biochemical properties of the radionuclides taken into the body or the behavior of the material in an individual is known, the licensee or registrant may:
4.9.3.1 Use that information to calculate the committed effective dose equivalent, and, if used, the licensee or registrant shall document that information in the individual's record; and
4.9.3.2 Upon prior approval of the Department, adjust the DAC or ALI values to reflect the actual physical and chemical characteristics of airborne radioactive material, for example, aerosol size distribution or density; and
4.9.3.3 Separately assess the contribution of fractional intakes of Class D, W, or Y compounds of a given radionuclide to the committed effective dose equivalent. See Appendix 4B.
4.9.4 If the licensee or registrant chooses to assess intakes of Class Y material using the measurements given in 4.9.1.2 or 4.9.1.3, the licensee or registrant may delay the recording and reporting of the assessments for periods up to 7 months, unless otherwise required by 4.52 or 4.53. This delay permits the licensee or registrant to make additional measurements basic to the assessments.
4.9.5 If the identity and concentration of each radionuclide in a mixture are known, the fraction of the DAC applicable to the mixture for use in calculating DAC-hours shall be either:
4.9.5.1 The sum of the ratios of the concentration to the appropriate DAC value, that is, D, W, or Y, from Appendix 4B for each radionuclide in the mixture; or
4.9.5.2 The ratio of the total concentration for all radionuclides in the mixture to the most restrictive DAC value for any radionuclide in the mixture.
4.9.6 If the identity of each radionuclide in a mixture is known, but the concentration of one or more of the radionuclides in the mixture is not known, the DAC for the mixture shall be the most restrictive DAC of any radionuclide in the mixture.
4.9.7 When a mixture of radionuclides in air exists, a licensee or registrant may disregard certain radionuclides in the mixture if:
4.9.7.1 The licensee or registrant uses the total activity of the mixture in demonstrating compliance with the dose limits in 4.6 and in complying with the monitoring requirements in 4.18.2; and
4.9.7.2 The concentration of any radionuclide disregarded is less than 10 percent of its DAC; and
4.9.7.3 The sum of these percentages for all of the radionuclides disregarded in the mixture does not exceed 30 percent.
4.9.8 When determining the committed effective dose equivalent, the following information may be considered:
4.9.8.1 In order to calculate the committed effective dose equivalent, the licensee or registrant may assume that the inhalation of one ALI, or an exposure of 2,000 DAC-hours, results in a committed effective dose equivalent of 0.05 Sv (5 rem) for radionuclides that have their ALIs or DACs based on the committed effective dose equivalent.
4.9.8.2 For an ALI and the associated DAC determined by the nonstochastic organ dose limit of 0.5 Sv (50 rem), the intake of radionuclides that would result in a committed effective dose equivalent of 0.05 Sv (5 rem), that is, the stochastic ALI, is listed in parentheses in Table 4B1 of Appendix 4B. The licensee or registrant may, as a simplifying assumption, use the stochastic ALI to determine committed effective dose equivalent. However, if the licensee or registrant uses the stochastic ALI, the licensee or registrant shall also demonstrate that the limit in 4.6.1.1.(2) is met.

6 CCR 1007-1-4.9

Colorado Register, Vol 37, No. 14. July 25, 2014, effective 8/14/2014
38 CR 02, January 25, 2015, effective 2/14/2015
38 CR 05, March 10, 2015, effective 3/30/2015
38 CR 12, June 25, 2015, effective 7/15/2015
38 CR 14, July 25, 2015, effective 8/14/2015
39 CR 02, January 25, 2016, effective 2/14/2016
39 CR 16, August 25, 2016, effective 9/14/2016
39 CR 22, November 25, 2016, effective 12/15/2016
40 CR 11, June 10, 2017, effective 6/30/2017
40 CR 20, October 25, 2017, effective 11/14/2017
42 CR 24, December 25, 2019, effective 1/14/2020
43 CR 14, July 25, 2020, effective 8/14/2020
43 CR 18, September 25, 2020, effective 10/15/2020
44 CR 11, June 10, 2021, effective 7/15/2021
44 CR 14, July 25, 2021, effective 8/14/2021
45 CR 22, November 25, 2022, effective 12/15/2022