780 CMR, ch. 51, ch. R4, R406.2

Current through Register 1538, January 3, 2025
Subsection R406.2

Add new subsection R406.2.1 as follows:

R406.2.1Through-wall Formwork Ties. Through-wall formwork ties shall be removed from both faces of the foundation walls which enclose basements, cellars, below-grade garages, or any space having the potential to be converted to useable or occupied space. Remaining holes shall be patched with hydraulic cement.

Delete the Exception for R408.7 Flood resistance.

780 CMR, ch. 51, ch. R4, R406.2

Amended by Mass Register Issue 1532, eff. 10/11/2024.