780 CMR, ch. 51, 7

Current through Register 1538, January 3, 2025
Chapter 7 - WALL COVERINS - AMENDMENTS

Add subsection R702.3.5.2 Ceiling Attachment - as follows:

R702.3.5.2Ceiling Attachment. Only designs or methods that use mechanical fasteners in accordance with Table R702.3.5 shall be used for attaching gypsum board to ceilings in buildings governed by 780 CMR 51.00 including manufactured buildings. Alternative designs, such as using adhesive only, are not permitted.

780 CMR, ch. 51, 7

Amended by Mass Register Issue 1532, eff. 10/11/2024.