Revise and Replace section R406.5 and Table T406.5 as follows:
Compliance based on an ERI analysis requires that the rated proposed design and confirmed built dwelling be shown to have an HERS index rating less than or equal to the appropriate value indicated in Table R406.5 when compared to the HERS index reference design for each dwelling unit prior to credit for onsite renewable electric generation.
TABLE R406.5 MAXIMUM ENERGY RATING INDEX
On-site Renewable Energy Application | Maximum HERS Index scorea, b | |
New construction | Whole house renovations; additions | |
None | 52 | 65 |
Solar Electric Generation | 55 | 70 |
Clean Space Heating | 55 | 70 |
Solar Electric & Clean Space Heating | 58 | 75 |
a Maximum HERS rating prior to onsite renewable electric generation in accordance with Section R406.5
b Where on-site renewable energy is included for compliance using the ERI analysis of Section R406.4, the building shall meet the mandatory requirements of SectionR406.2, and the building thermalenvelope shall be greater than or equal to the levels of efficiency and SHGC in Table R402.1.2 or Table R402.1.4 of the 2021 International Energy Conservation Code.
Add subsection R406.5.1 as follows:
780 CMR, ch. 51, ch. 4, R405, R406.5