780 CMR, 1028.13

Current through Register 1533, October 25, 2024
Subsection 1028.13 - Handrails

Ramped aisles having a slope exceeding one unit vertical in 15 units horizontal (6.7-percent slope) and aislestairs shall be provided with handrails located either at the side or within the aisle width.

Exceptions:

1.Handrails are not required for ramped aisles having a gradient no greater than one unit vertical in eight units horizontal (12.5-percent slope) and seating on both sides.
2.Handrails are not required if, at the side of the aisle, there is a guard that complies with the graspability requirements of handrails.
3.Handrail extensions are not required at the top and bottom of aislestairs and aisleramp runs to permit crossovers within the aisles.
1028.13.1Discontinuous handrails. Where there is seating on both sides of the aisle, the handrails shall be discontinuous with gaps or breaks at intervals not exceeding five rows to facilitate access to seating and to permit crossing from one side of the aisle to the other. These gaps or breaks shall have a clear width of at least 22 inches (559 mm) and not greater than 36 inches (914 mm), measured horizontally, and the handrail shall have rounded terminations or bends.
1028.13.2Intermediate handrails. Where handrails are provided in the middle of aislestairs, there shall be an additional intermediate handrail located approximately 12 inches (305 mm) below the main handrail.

780 CMR, 1028.13