526 CMR, § 10.06

Current through Register 1538, January 3, 2025
Section 10.06 - Non-destructive Testing (NDT)
(1)NDT Plan.
(a) A Ski Area Owner shall obtain all required non-destructive testing plans from the Manufacturer. The plan shall include the Non-destructive testing requirements and schedules. The NDT plan shall include provisions for the Non-destructive testing of all critical structural and mechanical components including grips, clips, hangers, chairs, and cabin and shall comply with ANSI.
(b) Where there is no Manufacturer to provide the required documents, the Ski Area Owner shall obtain a non-destructive testing plan prepared by a Registered Professional Engineer.
(2)NDT Testing. The Ski Area Owner shall have Non-destructive Testing performed in accordance with the NDT plan.
(3)NDT Report.
(a) All NDT testing shall be performed by a Level II or III certified NDT examiner.
(b) The certified NDT examiner performing the testing shall document their findings in a NDT Report, which shall be maintained by the Ski Area Owner for the life of the Tramway.
(c) The Ski Area Owner shall submit a NDT report to the Board with the License Application prior to the issuance of an annual License to operate the Tramway.

526 CMR, § 10.06