524 Mass. Reg. 8.4

Current through Register 1524, June 21, 2024
Section 8.4 - ELEVATOR SEISMIC REQIREMENTS

8.4.4 Car Enclosures, Car Doors and Gates, and Car Illumination

8.4.4.1 Top Emergency Exits

8.4.4.1.1 Delete and replace with:

8.4.4.1.1 The requirements specified in 2.14.1.5 shall apply except that the top emergency exit shall be so arranged that it can be opened from within the car by means of firefighter key number 3502 with a keyed spring-return cylinder-type lock and the top emergency exit shall opened from the top of the car without the use of a key. The possession of the firefighter key number 3502 shall be limited to trained fire department personnel and Massachusetts-licensed elevator mechanics. This key shall not be a part of a building master key system.

524 CMR 8.4

Amended by Mass Register Issue 1366, eff. 6/1/2018.