521 CMR, § 30.14

Current through Register 1530, September 13, 2024
Section 30.14 - CHILDREN'S WATER CLOSETS

Where provided, shall comply with the following:

30.14.1Clear floor space: Clear floor space for water closets shall comply with 521 CMR 30.5, Clear Floor Space. Clear floor space may be arranged to allow either a left-handed or right-handed approach.
30.14.2 Location: The center line of the water closet shall be located 11 inches (11 " = 279mm) from the nearest side wall for pre-kindergarten; 11 to 15(11" to 15" = 279mm to 381mm) for kindergarten to third grade and 15 to 18 inches (15" to 18" = 381mm to 457mm) for fourth grade to sixth grade. The water closet shall also be located 42 inches (42" = 1067mm) from the center line of the water closet to the opposite wall or closest edge of next fixture.
30.14.3 Height: Water closets shall be set at a height measured from the floor to the top of the seat as follows:

Pre-kindergarten:

111/2" to 121/2" (292mm to 318mm)

Kindergarten to third grade:

12" to 15" (305mm to 381mm)

Fourth grade to sixth grade:

15" to 17" (381mm to 432mm)

30.14.4 Flush Controls: Controls for flush valves on water closets used by children shall be mounted on the wide side of water closet within 20 to 30 inches (20" to 30" = 508mm to 762mm) above the floor.
30.14.5 Toilet paper dispensers: Toilet paper dispensers used by children shall be centered above finished floor, as follows:

Pre-kindergarten:

14" (356mm)

Kindergarten to third grade:

14" to 17" (356mm to 432mm)

Fourth grade to sixth grade:

17" to 19" (432mm to 483mm)

521 CMR, § 30.14