521 CMR, § 13.2

Current through Register 1533, October 25, 2024
Section 13.2 - PUBLIC USE AND COMMON USE AREAS

All public and common use areas shall be accessible and shall include but are not limited to areas where services are provided to the public, waiting areas, changing rooms, diagnostic and treatment areas, exam rooms, offices and meeting rooms, food services, gift shops, and emergency facilities, and toilet rooms.

13.2.1 Where examining tables are provided in exam rooms, they shall be adjustable in height from 15 inches (381mm) above the floor.
13.2.2 Counters across which transactions are conducted with patients and the public shall comply with the following:
a. Location: The counter shall be on an accessible route.
b. Length: A portion of the counter or an auxiliary counter shall be at least 36 inches (36" = 914mm) in length.
c. Height: That portion of the counter shall not exceed 36 inches (36" = 914mm) above the finished floor.
d.Clear floor space: Shall be provided in front of counter.

521 CMR, § 13.2