49 C.F.R. § 236.410

Current through November 30, 2024
Section 236.410 - Locking, hand-operated switch; requirements
(a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position, except:
(1) Where train speeds over the switch do not exceed 20 miles per hour;
(2) Where trains are not permitted to clear the main track;
(3) Where a signal is provided to govern train movements from the auxiliary track to the signaled track; or
(4) On a signaled siding without intermediate signals where the maximum authorized speed on the siding does not exceed 30 miles per hour.
(b) Approach or time locking shall be provided and locking may be released either automatically, or by the control operator, but only after the control circuits of signals governing movement in either direction over the switch and which display aspects with indications more favorable than "proceed at restricted speed" have been opened directly or by shunting of track circuit.
(c) Where a signal is used in lieu of electric or mechanical lock to govern movements from auxiliary track to signaled track, the signal shall not display an aspect to proceed until after the control circuits of signals governing movement on main track in either direction over the switch have been opened, and either the approach locking circuits to the switch are unoccupied or a predetermined time interval has expired.

Note: Railroads shall bring all hand-operated switches that are not electrically or mechanically locked and that do not conform to the requirements of this section on the effective date of this part into conformity with this section in accordance with the following schedule:

Not less than 33% during calendar year 1984.

Not less than 66% during calendar year 1985.

The remainder during calendar year 1986.

49 C.F.R. §236.410

33 FR 19684, Dec. 25, 1968, as amended at 49 FR 3386, Jan. 26, 1984; 75 FR 2699 , Jan. 15, 2010