49 C.F.R. § 179.100-16

Current through May 31, 2024
Section 179.100-16 - Attachments
(a) Reinforcing pads must be used between external brackets and shells if the attachment welds exceed 6 linear inches of¼ -inch fillet or equivalent weld per bracket or bracket leg. When reinforcing pads are used, they must not be less than one-fourth inch in thickness, have each corner rounded to a 1-inch minimum radius, and be attached to the tank by continuous fillet welds except for venting provisions. The ultimate shear strength of the bracket-to-reinforcing pad weld must not exceed 85 percent of the ultimate shear strength of the reinforcing pad-to-tank weld.
(b) Attachments not otherwise specified shall be applied by approved means.

49 C.F.R. §179.100-16

29 FR 18995, 12/29/1964. Redesignated at 32 FR 5606, 4/5/1967, and amended by Amdt. 179-10, 36 FR 21346, 11/6/1971