Current through November 30, 2024
Section 173.322 - Ethyl chlorideEthyl chloride must be packaged in any of the following single or combination non-bulk packagings which meet Packing Group I performance level requirements:
(a) In 4C1, 4C2, 4D or 4F wooden boxes with glass, earthenware, or metal inner receptacles not over 500 g (17.6 ounces) capacity each;(b) In 4G fiberboard boxes with glass, earthenware, or metal inner receptacles not over 500 g (17.6 ounces) capacity each. Outer packagings may not exceed 30 kg (66 pounds) gross weight;(c) In 1A1 drums of not over 100 L (26 gallons) capacity each; or(d) In specification cylinders as prescribed for any compressed gas except acetylene. Cylinders made of aluminum alloy are not authorized.(e) In capsules under the following conditions:(1) The mass of gas must not exceed 150 g (5.30 ounces) per capsule;(2) The capsule must be free of faults liable to impair its strength;(3) The leakproofness integrity of the closure must be maintained by a secondary means (e.g., cap, crown, seal, binding, etc.) capable of preventing any leakage of the closure while in transportation; and(4) The capsules must be placed in a strong outer packaging suitable for the contents and may not exceed a gross mass of 75 kg (165 pounds).Amdt. 173-224, 55 FR 52667, Dec. 21, 1990, as amended at 74 FR 2266 , Jan. 14, 2009; 76 FR 3381 , Jan. 19, 2011