46 C.F.R. § 176.806

Current through May 31, 2024
Section 176.806 - Electrical

At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following:

(a) Inspection of all cable as far as practicable without undue disturbance of the cable or electrical apparatus;
(b) Test of circuit breakers by manual operation;
(c) Inspection of fuses including ensuring the ratings of fuses are suitable for the service intended;
(d) Inspection of rotating electrical machinery essential to the routine operation of the vessel;
(e) Inspection of all generators, motors, lighting fixtures and circuit interrupting devices located in spaces or areas that may contain flammable vapors;
(f) Inspection of batteries for condition and security of stowage;
(g) Operational test of electrical apparatus, which operates as part of or in conjunction with a fire detection or alarms system installed on board the vessel, by simulating, as closely as practicable, the actual operation in case of fire; and
(h) Operational test of all emergency electrical systems.

46 C.F.R. § 176.806