Current through October 31, 2024
Section 172.105 - Extent of damageFor the purpose of § 172.103 , design calculations must include both side and bottom damage, applied separately. Damage must consist of the most disabling penetration up to and including penetrations having the following dimensions:
(a) Side damage must be assumed to be as follows:(1) Longitudinal extent-6 feet (183 centimeters).(2) Transverse extent-30 inches (76 centimeters).(3) Vertical extent-from the baseline upward without limit.(b) Bottom damage must be assumed to be 15 inches (38 centimeters) from the baseline upward.