46 C.F.R. § 169.690

Current through May 31, 2024
Section 169.690 - Lighting branch circuits

Each lighting branch circuit must meet the requirements of § 111.75-5 of this chapter, except that-

(a) Appliance loads, electric heater loads, and isolated small motor loads may be connected to a lighting distribution panelboard; and
(b) Branch circuits in excess of 30 amperes may be supplied from a lighting distribution panelboard.

46 C.F.R. §169.690