46 C.F.R. § 169.529

Current through November 30, 2024
Section 169.529 - Description of lifeboat equipment
(a) All lifeboat equipment must meet the requirements under 46 CFR 199.175 , except as provided in paragraph (b) of this section.
(b) The following equipment, carried in addition to the equipment required under 46 CFR 199.175 , must meet the following requirements:
(1)Cover, protecting. The cover must be of highly visible color and capable of protecting the occupants against exposure. A cover is not required for fully enclosed lifeboats.
(2)Ditty bag. The ditty bag must consist of a canvas bag or equivalent and must contain a sailmaker's palm, needles, sail twine, marline, and marlin spike, except that motor-propelled lifeboats need not carry a ditty bag.
(3)Mast and sail. A unit, consisting of a standing lug sail together with the necessary spars and rigging, must be provided in accordance with table 1 to this section, except that motor-propelled lifeboats need not carry a mast or sails. The sails must be of good quality canvas, or other material acceptable to the Commandant, colored Indian Orange (Cable No. 70072, Standard Color Card of America; incorporated by reference, see § 169.115 ). Rigging must consist of galvanized wire rope not less than 3/16-inch in diameter. The mast and sail must be protected by a suitable cover.

Table 1 to § 169.529

Length of lifeboat, feetStanding lug sailCommercial designation numberMast1Yard1
Over-Not over-Area, square feetLuff and head lengthsLeach lengthFoot lengthClew to throatOunces per square yardLengthDiameter, inchesLengthDiameter, inches
FeetInchesFeetInchesFeetInchesFeetInchesFeetInchesFeetInches
1758511121810101014.351011236112
1719746813810012214.35101263782
1921937515111213814.3510131031/28521/2
212311383161112415114.351015231/29321/2
23251359018613616614.351016641003
252715899200147171017.508171041093
272918110521515719117.50819241/211531/4
293120311022816620320.74620641/212031/4
312

1 Mast lengths measured from heel to center of upper halyard sheave. Mast diameters measured at thwart. Mast and yard shall be of clear-grained spruce, fir, or equivalent.

2 Subject to special consideration.

46 C.F.R. §169.529

USCG-2020-0107, 87 FR 68306 , Nov. 14, 2022