Current through September 30, 2024
Section 164.008-5 - Test report(a) The test report required by § 164.008-7 (e) and (g) shall include at least the following: (1) Name of manufacturer.(3) Test conditions and date of test.(4) Description of the panel tested giving size, thickness, density, detail of joint and method of assembling in test furnace.(5) Complete time-temperature data, including initial temperature, for each thermocouple together with curves of average temperature for the unexposed surface of the insulation and the thermocouple recording the highest temperature. In addition, for § 164.008-7(g)(2) complete time-temperature data consisting of a numerical time-temperature table for each furnace and each surface of insulation thermocouple together with the initial temperature of each thermocouple.(6) A log setting forth the observer's notes relative to deflections, smoke or gas emission, glow, flame emission, and any other important data. The time of each observation should be noted.(7) Complete observations on the appearance of cracks and data on the testing of the cracks as specified in § 164.008-4(b) .(8) Photographs of both sides of the panel before and after testing.(9) Summary of test results.CGFR 69-72, 34 FR 17500, Oct. 29, 1969; 34 FR 19030, Nov. 29, 1969