Section 162.050-17 - Separator test rig(a) This section contains requirements for test rigs used in approval testing of separators. A diagram of a typical test rig is shown in Figure 162.050-17(a). FIGURE 162.050-17(a)-SEPARATOR TEST RIG
View Image
(b) Each mixture pump on a test rig must-(1) Be a centrifugal pump capable of operating at 1,000 revolutions per minute or more;(2) Have a delivery capacity of at least 1.5 times the maximum throughput at which the separator being tested is designed to operate;(3) Have a maximum delivery pressure that is equal to or greater than the maximum influent pressure at which the separator is designed to operate; and(4) Have either bypass piping to its suction side or a throttle valve or orifice on its discharge side.(c) The inlet piping of the test rig must be sized so that-(1) Influent water flows at a Reynolds Number of at least 10,000;(2) The influent flow rate is between one and three meters per second; and(3) Its length is at least 20 times its inside diameter.(d) Each sample point on a test rig must meet the design requirements described in Figure 162.050-17(d) and must be in a vertical portion of the test rig piping. FIGURE 162.050-17(d)-SAMPLE POINT
View Image