46 C.F.R. § 153.966

Current through September 30, 2024
Section 153.966 - Discharge by liquid displacement

The person in charge of cargo transfer may not authorize cargo discharge by liquid displacement unless the liquid supply line to the tank has:

(a) A safety relief or pressure reducing valve set to operate at no more than 80 percent of the tank's relief valve setting; and
(b) A manual control valve between the tank and the supply line's safety relief valve or pressure reducing valve.

46 C.F.R. § 153.966