46 C.F.R. § 153.208

Current through September 30, 2024
Section 153.208 - Ballast equipment
(a) Except for the arrangement described in paragraph (b) of this section no piping that serves a dedicated ballast tank that is adjacent to a cargo tank may enter an engine room or accommodation space.
(b) Piping used only to fill a dedicated ballast tank adjacent to a cargo tank may enter an engine room or accommodation space if the piping has a valve or valving arrangement:
(1) Within the part of the tankship where a containment system may be located under § 153.234 ;
(2) That allows liquid to flow only towards that ballast tank (such as a check valve); and
(3) That enables a person to shut off the fill line from the weatherdeck (such as a stop valve).
(c) Except as prescribed in paragraph (d) of this section, pumps, piping, vent lines, overflow tubes and sounding tubes serving dedicated ballast tanks must not be located within a cargo containment system.
(d) Each vent line, overflow tube and sounding tube that serves a dedicated ballast tank and that is located within a cargo containment system must meet § 32.60-10(e)(2) of this chapter.

46 C.F.R. §153.208