Section 111.97-7 - Distribution(a) Each distribution panelboard for a watertight door system must be above the uppermost continuous deck and must have means for locking.(b) Each feeder supplying a watertight door operating system must be above the uppermost continuous deck.(c) Each watertight door operating system must have a separate branch circuit.