46 C.F.R. § 111.107-1

Current through May 31, 2024
Section 111.107-1 - Industrial systems
(a) For the purpose of this subpart, an industrial system is a system that-
(1) Is not a ship's service load, as defined in § 110.15-1 ;
(2) Is used only for the industrial function of the vessel;
(3) Is not connected to the emergency power source; and
(4) Does not have specific requirements addressed elsewhere in this subchapter.
(b) An industrial system that meets the applicable requirements of NFPA 70 (incorporated by reference; see § 110.10-1 of this subchapter) must meet only the following:
(1) Part 110, subpart 110.25, of this chapter-Plan Submittal.
(2) Subpart 111.01 of this part-General.
(3) Subpart 111.05 of this part-Equipment Ground, Ground Detection, and Grounded Systems.
(4) Sections 111.12-1(b) and 111.12-1(c) -Prime movers.
(5) Sections 111.30-1 , 111.30-5(a) , and 111.30-19(a) -Switchgear.
(6) Subpart 111.105 of this part-Hazardous Locations.
(c) Cables that penetrate a watertight or fire boundary deck or bulkhead must-
(1) Be installed in accordance with 46 CFR 111.60-5 and meet the flammability-test requirements of either IEEE 1202, IEC 60332-3-22:2018, or IEC 60332-3-21:2018, Category A or A F/R (all incorporated by reference; see § 110.10-1 of this subchapter); or
(2) Be specialty cable installed in accordance with § 111.60-2 .

46 C.F.R. §111.107-1

CGD 94-108, 61 FR 28286, June 4, 1996, as amended at 62 FR 23910, May 1, 1997; USCG-2003-16630, 73 FR 65201, Oct. 31, 2008
88 FR 16368, 4/17/2023