46 C.F.R. § 32.56-21

Current through October 31, 2024
Section 32.56-21 - Openings in exterior boundaries: Accommodation, service, and control spaces-T/ALL

The following exterior boundaries of accommodation, service, and control spaces, except wheelhouses, must have no openings, and portlights must be of a fixed type with easily operable steel covers on the inside:

(a) The exterior boundaries that face the cargo area.
(b) The portion of the exterior boundaries within 3 meters (10 feet) or the length of the vessel divided by 25, whichever is greater, except that the distance need not exceed 5 meters (16.4 feet), of these boundaries.

46 C.F.R. § 32.56-21