42 C.F.R. § 84.255

Current through September 30, 2024
Section 84.255 - Requirements for end-of-service-life indicator
(a) Each canister or cartridge submitted for testing and approval in accordance with §§ 84.252 , 84.253 , and 84.254 shall be equipped with a canister or cartridge end-of-service-life indicator which shows a satisfactory indicator change or other obvious warning before 1 ppm vinyl chloride penetration occurs. The indicator shall show such change or afford such warning at 80 ±10 percent of the total service life to 1 ppm leakage, as determined by continuing each test described in §§ 84.252(b) , 84.253(b) , and 84.254(b) until a 1 ppm leakage of vinyl chloride occurs.
(b) The applicant shall provide sufficient pretest data to verify the performance of the end-of-service-life indicator required in paragraph (a) of this section.

42 C.F.R. §84.255