40 C.F.R. § 1065.284

Current through May 31, 2024
Section 1065.284 - Zirconium dioxide (ZrO[2]) air-fuel ratio and O[2] analyzer
(a)Application. You may use a zirconia (ZrO2) analyzer to measure air-to-fuel ratio in raw exhaust for continuous sampling. You may use O2 measurements with intake air or fuel flow measurements to calculate exhaust flow rate according to § 1065.650 .
(b)Component requirements. We recommend that you use a ZrO2 analyzer that meets the specifications in Table 1 of § 1065.205 . Note that your ZrO2-based system must meet the linearity verification in § 1065.307 .

40 C.F.R. §1065.284

70 FR 40516, July 13, 2005, as amended at 76 FR 57443, Sept. 15, 2011; 79 FR 23762, Apr. 28, 2014
88 FR 4673, 3/27/2023