40 C.F.R. § 421.295

Current through May 31, 2024
Section 421.295 - Pretreatment standards for existing sources

Except as provided in 40 CFR 403.7 and 403.13 , any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources. The mass of wastewater pollutants in secondary tin process wastewater introduced into a POTW must not exceed the following values:

(a) Tin smelter SO2 scrubber.

PSES for the Secondary Tin Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of crude tapped tin produced
Arsenic12.7905.703
Lead2.5751.196
Iron11.0405.611
Tin3.4952.024

(b) Dealuminizing rinse.

PSES for the Secondary Tin Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of dealuminized scrap produced
Lead0.0100.005
Cyanide (total)0.0070.003
Fluoride1.2250.697
Tin0.0130.008

(c) Tin mud acid neutralization filtrate.

PSES for the Secondary Tin Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of neutralized dewatered tin mud produced
Lead1.4130.656
Cyanide (total)1.0090.404
Fluoride176.600100.400
Tin1.9181.110

(d) Tin hydroxide wash.

PSES for the Secondary Tin Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of tin hydroxide washed
Lead3.3471.554
Cyanide (total)2.3910.956
Fluoride418.400237.900
Tin4.5422.630

(e) Spent electrowinning solution from new scrap.

PSES for the Secondary Tin Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of cathode tin produced
Lead4.7042.184
Cyanide (total)3.3601.344
Fluoride588.000334.300
Tin6.3843.696

(f) Spent electrowinning solution from municipal solid waste.

PSES for the Secondary Tin Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of MSW scrap used as raw material
Lead0.0330.015
Cyanide (total)0.0240.010
Fluoride4.1652.368
Tin0.0450.026

(g) Tin hydroxide supernatant from scrap.

PSES for the Secondary Tin Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of tin metal recovered from scrap
Lead15.5807.233
Cyanide (total)11.1304.451
Fluoride1,947.0001,107.000
Tin21.14012.240

(h) Tin hydroxide supernatant from plating solutions and sludges.

PSES for the Secondary Tin Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of tin metal recovered from plating solutions and sludges
Lead32.2014.95
Cyanide (total)23.009.20
Fluoride4,025.002,289.00
Tin43.7025.30

(i) Tin hydroxide filtrate.

PSES for the Secondary Tin Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of tin metal produced
Lead7.0123.256
Cyanide (total)5.0092.004
Fluoride876.500498.400
Tin9.5175.510

40 C.F.R. §421.295